Data Acquisition System Logger StationⅡ DL2800

Data Acquisition System Logger StationⅡ DL2800

32-Channels with Multiple Sensor Type Direct Input
Control and Measure Both Stand-alone & via Network

Features

Remote Control Measurement & Recording via Network

Up to eight (8) DL2800 units (256 channels) can be remotely Network controlled via Ethernet connection.

Multi-channel Measurements

Each mainframe provides 32 Channel capacity via 16 dual channel AP-Amplifier Module slots. Additionally, 16 Logic/Event Digital Inputs are provided standard.

Stand-alone Operation

Simply connect user's monitor, keyboard and USB mouse to operate the DL2800 as a selfcontained stand-alone Data Logger

Common Signal Amplifiers

Plug-in Signal Input Conditioning Amplifier Modules are the same as used with the RA1000 and RA2000 series Data Acquisition Recorders. Each isolated Amplifier can be interchanged among units for measurement versatility.

Three (3) Powerful Measurement Modes

  • Memory Mode - Record Fast Events
  • HDD Mode - Long-term Measurements
  • Multi Mode - Combined Memory & HDD

Rack Mounting Available

Optional 19"rack mount adapters are available for the DL2800 mainframe. A front panel located HDD simplifies maintenance.

Direct Input from Various Sensors

Plug-in AP Series Amplifiers used with RA recorders enable direct sensor input for Voltage, Vibration, Strain, Temperature, Pressure, Pulse, etc.

Multi-unit Synchronization Option

Time synchronize up to 10 each DL2800 mainframes (320 channels) with this option when operating in the Memory Recorder mode.

Make Both Transient and Longterm Recordings

Transients: Up to 2µS sampling Long-term: Record for 60-days at 10mS sampling on 32 channels.

Basic Specifications

Number of channels 32 channels (16 slots) + 16 digital input (mainframe)
Storage device Internal memory: 32MW,Built-in HDD: 40GB (includes system domain 5GB)
USB memory using the USB port
Interfaces Ethernet (10BASE-T/100BASE-TX): for control with communication command (std)
USB mouse: for USB memory, 2 ports (standard)
RS-232C: for control by communication command or UPS shut-down (optional)
Sampling speed Max 2µs (500kS/s) **Depends on recording drive and number of channels
Measuring mode Selectable from Memory Recorder, HDD Recorder and Multi Recorder modes
  Memory Recorder Mode Records measured data onto internal memory by set trigger. For fast or accidental events
  Memory capacity 32MW (1MW per channel when using 32 channels)
Memory division 1, 2, 4, 8, 16, 32, 64, 128 divisions
Measuring Operation One time, repeat, endless
HDD Recorder Mode Records measured data on HDD at real time. For long-term measurement.
  HDD capacity Max 35GB
Starting condition Press start key or set start time.
Measuring Operation Normal or ring (repeat recording at set time period)
Recording method Sample: record data at set sampling speed
Peak: record max and min value at every 2µs sampling during set recording period
Multi Recorder Mode Combination of Memory & HDD recording. Steady-state and transient events can be recorded simultaneously.
Monitor output XGA (analog RGB, 1024 x 768 dots)
Operating environment Temperature: 5 to 40℃, humidity: 35 to 80%RH (Without condensation.
Humidity must be 45%RH or lower if temperature is 30℃ or over.)
Power supply 90 to 264VAC, frequency: 50 or 60Hz
Power consumption Max approx. 170VAC (when using USB port and 16 AP11-103s installed)
Dimensions Approx. 431 (W) x 244 (H) x 307 (D) (pads on corners included but not other projections)
Weight Mainframe only: 10.5kg or less
Mainframe, 1 optional unit & 12 AP11-101s: 13.5kg or less

Connection with PC

Data recorded on DL2800 can be transferred to the PC via USB memory or Ethernet. The optional PC software ‘Unifizer’allows users to do calculation, report generation and file conversion of the data.

Connection with PC

Recordable Time on Memory Devices

Sampling Speed Internal memory (32MW) HDD (35GB) *1 USB memory (512MB) *1
w/ 1ch w/ 32chs w/ 1ch w/ 32chs w/ 1ch w/ 32chs
2µs 1.1min 2.1sec 9.7hrs - - -
5µs 2.8min 5.2sec 24hrs - - -
20µs 11min 21sec 4days 3hrs - -
50µs 28min 52sec 10days 7.6hrs - -
100µs 56min 1.8min 20days 15hrs - -
500µs 4.7hrs 8.7min 101days 3.2days - -
1ms 9.3hrs 17min 203days 6.3days 3days 2hrs
50ms 19days 15hrs 28years 316days 148days 4.6days
100ms 39days 29hrs 56years 1.7years 296days 9.3days

Above data is calculated value.

  • *1: Value at sample filing by integers. At peak filing, the recordable time becomes half of above data.

PC Software

Unifizer: NS3000 Series
Unifizer: NS3000 Series
  • Enables remote control of DL2800 by PC.
  • Real-time data transfer from DL2800 to the PC via Ethernet.
    (Max speed: 100µs. Up to 8 DL2800s can be connected.)
  • Display of replayed data (waveform, X-Y, physical data)
  • Recorded data can be converted to CSV and output to report easily.
  • Various math functions:
    Calculations between channels, power, square root, absolute value, common logarithm, exponential, RMS, trigonometric function,moving average, etc.

Main Unit & Accessories

Item Model Specification
Logger Station DL2800  

Input Amplifiers Unit

Item Model Specification
2ch High Resolution DC Amp AP11-101 Input: ±100mV to ±500V, A/D: 16 bits
2ch FFT Amp AP11-102 Anti-aliasing filter: 72dB/OCT, with power supply for sensor
2ch High speed DC Amp AP11-103 Input: ±100mV to ±500V, A/D: 12 bits
2ch AC Strain Amp *1 AP11-104A Frequency characteristics: 2kHz, Bridge power: 5kHz
Event Amp AP11-105 Input: 8 logic (voltage/contact)
2ch TC/DC Amp AP11-106A Input: R, T, J, K, W (±100mV to ±50V), A/D resolution: 15 bits
TC/DC Amp AP11-107 Input: R, T, J, K (±10mV to ±50V), A/D resolution: 14 bits
F/V Converter AP11-108 Input: 1Hz to 10kHz
2ch Vibration/RMS Amp AP11-109 Input: ±100mV to ±500V, w/ power supply for sensor
2ch DC Strain Amp AP11-110 Input: 800µε to 20kµε(BV=5V), 2kµε to 50kµε(BV=2V)
2ch Zero Suppression Amp AP11-111 Input: ±100mV to ±500V, A/D: 16-bit
  • *1: Optional AC Bridge Power Unit (RA23-116) is required.

Optional Unit

Item Model Specification
Remote Unit RA23-112 Use external signals to start/stop recording and to control other functions
RS-232C Unit RA23-114 For control by communication command or for shutdown by UPS
AC Bridge Power Unit RA23-116 AC bridge power unit for 2ch AC Strain Amp (AP11-104A)
Synchronization Unit RA28-111 For multiple DL2800 synchronization (up to 10 units)

PC Software:Unifizer

Item Model Specification
Online Basic Set NS3100-P01 For RA1000/2000 series and L2800
Compatible with Windows 2000 & XP
Offline Set NS3200-P01
  • * Contents of this catalog including specifications are subject to change without prior notice.
Get ADOBE® READER®
To open .pdf documents, you will need the latest Adobe Acrobat Reader software.
Download Adobe software from left.

If you cannot open the document on your web-browser,
right-click the link and choose option 'Save Target As' to download the pdf into your local storage medium, first.
Then, launch the saved file from your storage device (i.e. HDD of your PC etc.).

To Top of  Page


Please feel free to request for the estimate and the brochure of the Infrared Camera & Thermography imager & Thermal camera.

About Infrared camera & Thermography imager & Thermal camera, ask NEC Avio Infrared Technologies.